1.ОБОРУДВАНЕ ЗА БЕЗРАЗРУШИТЕЛЕН КОНТРОЛ:

2.ОБОРУДВАНЕ ЗА ИЗПИТВАНЕ, ИЗМЕРВАНЕ И КОНТРОЛ:

Enter the text in the picture :
Click here to change the image

BulgarianEnglish
NDT Equipment and Accesories
Measuring and Testing Instruments


Electromagnetic Acoustic Transducer (EMAT)

Other Thickness Gage Transducers

  • For use with 37DL PLUS and 38DL PLUS
Transducer
Part
Number
Frequency Tip
Diameter
Transducer
Type
Connector
Type
Connector
Location
Range in Steel Temp. Range Holder
  MHz inches mm       inches mm °F °C  
V260-SM 15 0.080 2 Sonopen® Microdot Straight 0.02 - 0.400 0.5 - 10 32 to 122 0 to 50 SLH-V260-
SM
V260-RM 15 0.080 2 Sonopen Microdot Right Angle 0.02 - 0.400 0.5 - 10 32 to 122 0 to 50 -
V260-45 15 0.080 2 Sonopen Microdot 45˚ Handle 0.02 - 0.400 0.5 - 10 32 to 122 0 to 50 -
D7906-SM* 5.0 0.434 11 Thru-Coat Dual Microdot Straight 0.040 - 2.0 1.0 - 50 32 to 122 0 to 50 F152 / F152A
D7906-RM* 5.0 0.434 11 Thru-Coat Dual Microdot Right Angle 0.040 - 2.0 1.0 - 50 32 to 122 0 to 50 F152 / F152A
D7908* 7.5 0.283 7.2 Thru-Coat Dual Potted Potted 0.040 - 1.5 0.71 - 37 32 to 122 0 to 50 -
M2017 20 0.250 6.35 Internal Oxide
Scale
Microdot Right Angle Steel:
0.020 - 0.50
Oxide:
0.010 - 0.050
Steel:
0.5 - 12
Oxide:
0.25 - 1.25
32 to 122 0 to 50 2127
M2091 20 0.250 6.35 Replaceable
Delay Line
Shear Wave
Microdot Right Angle Steel:
0.020 - 0.50
Oxide:
0.006 - 0.050
Steel:
0.5 - 12
Oxide:
0.150 - 1.25
32 to 122 0 to 50 2127
E110-SB† - 1.25 28.5 EMAT BNC Straight 0.080 - 5 2.0 - 125 32 to 176 0 to 80 -

* Compatible with MG2-XT and MG2-DL
† Adaptor required for E110 (part number 1/2XA/E110).

 

Electromagnetic Acoustic Transducer (EMAT)

Electromagnetic Acoustic Transducers are single element transducers that employ a magnetostrictive effect to transmit and receive ultrasonic waves. Part number E110-SB.

Advantages

• No need to remove external scale
• No couplant required
• Use in contact with or at a small distance from surface

Applications

• External oxide scaled surfaces
• Use with 37DL PLUS** or 38DL PLUS** thickness gages, EPOCH LT**, EPOCH 4 PLUS,
EPOCH XT, EPOCH LTC, EPOCH 600 or EPOCH 1000 flaw detectors
* Temperature specification are 32 °F to 140 °F (0 °C to 60 °C) for continuous contact and 176 °F (80 °C) for intermittent contact, defined as 10 seconds in contact with part and 60 seconds of cooling time.
**Adaptor required. Please order separately. Part number 1/2XA/E110

 

 

Gage Dual Cables

Cable Part Number For Use With Length Cable Type Plug Type
    feet meters    
LCMD-316-5B D790-SM 5.0 1.5 Standard Straight
RLCMD-316-5B D790-SM 5.0 1.5 Standard Rt Angle
LCMD-178-5B SSA D790-SM 5.0 1.5 Armored Straight
RLCMD-178-5B SSA D790-SM 5.0 1.5 Armored Rt Angle
LCLD-316-5G D790-RL 5.0 1.5 Standard Straight
LCLD-316-5H D790-SL 5.0 1.5 Standard Straight
LCMD-316-5C D791-RM 5.0 1.5 Standard Straight
LCMD-316-5D D797-SM 5.0 1.5 Standard Straight
LCMD-316-5J D798-SM 5.0 1.5 Standard Straight
LCMD-316-5L D7906-SM 5.0 1.5 Standard Straight
LCMD-316-5N D7906-RM 5.0 1.5 Standard Straight
LCLPD-78-5 MTD705 5.0 1.5 Standard Straight
LCM-74-4 V260-SM, V260-RM,
V260-45, M2017
4.0 1.2 Standard -
LCM-188-4 SSA V260-SM, V260-RM,
V260-45, M2017
4.0 1.2 Armored -
LCB-74-4 E110-SB 4.0 1.2 Standard -