NDT Equipment and Accesories
Measuring and Testing Instruments


Spotweld Transducers

Olympus NDT ultrasonic spotweld transducers are specifically designed to provide optimal performance for nondestructive testing of numerous types of spotwelds, including those used in automotive and industrial applications. Ultrasonic inspection of spotwelds involves the analysis of what is known as the "ringdown" of sound within the weld nugget. Unlike many other direct measurement techniques, spotweld inspection looks at the characteristics of the multiple echoes returned from sound energy ringing within the weld nugget. Echo spacing, sound attenuation, and intermediate echo detection are some of the indicators of weld quality that are analyzed by trained inspectors.

Download the Spotweld Transducers Datasheet

 

Top Row: Transducer, Water Column, Membranes Bottom Row: Transducer, Delay Line, Delay Line Retaining Ring

PANAMETRICS-NDT™

Our new Panametrics-NDT transducers have excellent signal-to-noise ratios due to broadband design, which is critical for distinguishing good welds from poor welds. These transducers are available in a multitude of sizes in 0.5 mm increments to ensure that the proper transducers are available for a variety of weld nugget sizes. Element sizes are engraved with both English and metric units for worldwide use. The versatile design of these spotweld transducers allows them to be used with either a soft membrane captive water column or a hard tip delay line. Panametrics-NDT transducers, delay lines, and water columns are sold separately.

HARISONIC®

Olympus NDT also offers a series of PVDF (polymer) transducers from the Harisonic line specifically for use with custom captive water column systems. These polymer transducers are very high resolution transducers due to the very broad bandwidth of the PVDF elements. These Harisonic probes are only for use with captive water columns, which come standard with the purchase of the transducer.

PANAMETRICS-NDT™

Select either delay line or water column  (Transducers, delay lines, delay line retaining rings, water columns, and membranes need to be ordered separately).

 

TRANSDUCER
PART NUMBER
FREQ
MHZ
DIAMETER
(MM)
DIAMETER
(INCHES)
DELAY LINE*
Choose Appropriate Diameter
DELAY LINE
RETAINING
RING
WATER
COLUMN
V2325 15 2.5 0.098 SWDL-25 (2.5 mm) SWDL-27 (2.7 mm) SWRR-1 DLCW-1003
V2330 15 3 0.118 SWDL-30 (3.0 mm) SWDL-32 (3.2 mm) SWRR-1 DLCW-1003
V2335 15 3.5 0.138 SWDL-35 (3.5 mm) SWDL-37 (3.7 mm) SWRR-2 DLCW-2003
V2340 15 4 0.157 SWDL-40 (4.0 mm) SWDL-42 (4.2 mm) SWRR-2 DLCW-2003
V2345 15 4.5 0.177 SWDL-45 (4.5 mm) SWDL-47 (4.7 mm) SWRR-2 DLCW-2003
V2350 15 5 0.197 SWDL-50 (5.0 mm) SWDL-52 (5.2 mm) SWRR-2 DLCW-2003
V2355 15 5.5 0.217 SWDL-55 (5.5 mm) SWDL-57 (5.7 mm) SWRR-2 DLCW-2003
V2360 15 6 0.236 SWDL-60 (6.0 mm) SWDL-62 (6.2 mm) SWRR-2 DLCW-2003
V2365 15 6.5 0.256 SWDL-65 (6.5 mm) SWDL-67 (6.7 mm) SWRR-3 DLCW-3003
V2380 15 8 0.315 SWDL-80 (8.0 mm) SWDL-82 (8.2 mm) SWRR-3 DLCW-3003
V2425 20 2.5 0.098 SWDL-25 (2.5 mm) SWDL-27 (2.7 mm) SWRR-1 DLCW-1003
V2430 20 3 0.118 SWDL-30 (3.0 mm) SWDL-32 (3.2 mm) SWRR-1 DLCW-1003
V2435 20 3.5 0.138 SWDL-35 (3.5 mm) SWDL-37 (3.7 mm) SWRR-2 DLCW-2003
V2440 20 4 0.157 SWDL-40 (4.0 mm) SWDL-42 (4.2 mm) SWRR-2 DLCW-2003
V2445 20 4.5 0.177 SWDL-45 (4.5 mm) SWDL-47 (4.7 mm) SWRR-2 DLCW-2003
V2450 20 5 0.197 SWDL-50 (5.0 mm) SWDL-52 (5.2 mm) SWRR-2 DLCW-2003
V2455 20 5.5 0.217 SWDL-55 (5.5 mm) SWDL-57 (5.7 mm) SWRR-2 DLCW-2003
V2460 20 6 0.236 SWDL-60 (6.0 mm) SWDL-62 (6.2 mm) SWRR-2 DLCW-2003
V2465 20 6.5 0.256 SWDL-65 (6.5 mm) SWDL-67 (6.7 mm) SWRR-3 DLCW-3003

Captive Water Column Membranes (Includes O-Rings)

 

fits DLCW-1003 fits DLCW-2003
fits DLCW-3003
Part Number Desc. (qty.) Part Number Desc. (qty.) Part Number Desc. (qty.)
DLCW-1003-MK25 25 Std. DLCW-2003-MK25 25 Std. DLCW-3003-MK25 25 Std.
DLCW-1003-MK50 50 Std. DLCW-2003-MK50 50 Std. DLCW-3003-MK50 50 Std.
DLCW-1003-MKX25 25 Hvy. Duty DLCW-2003-MKX25 25 Hvy. Duty DLCW-3003-MKX25 25 Hvy. Duty
DLCW-1003-MKX50 50 Hvy. Duty DLCW-2003-MKX50 50 Hvy. Duty DLCW-3003-MKX50 50 Hvy. Duty

Harisonic®

Purchase of transducer includes water column, one O-ring, and one membrane.

Purchase of additional membranes is recommended.

PVDF Water Column Transducers
Part number Frequency mhz Size (mm)
HPF-0315 20 3.15
HPF-0360 20 3.6
HPF-0400 20 4
HPF-0450 20 4.5
HPF-0500 20 5
HPF-0560 20 5.6
HPD-0630 20 6.3

 

  PVDF
Water Column
O-RINGS Membranes
Compatible with
Transducers
Part Number Part Number Desc. (qty.) Part Number Desc.
(qty.)
3.15 to 4.5 mm HAX-3131 HAX-3134 10 HAX-3140 10
HAX-3135 25 HAX-1991 25
5 to 5.6 mm HAX-3132 HAX-3136 10 HAX-3142 10
HAX-3137 25 HAX-2002 25
6.3 mm HAX-3143 HAX-3138 10 HAX-3140 10
HAX-3139 25 HAX-3103 25

 

 